Overview Overall dimensions: length 340X high 230X width 80mm, the mounting hole is 16 mm Adopt high-performance processor, improve data processing speed and control reliability easy to adapt to a variety of electronic hysteresis display accuracy 1g voltage adjustment accuracy of 0.01 times JDKZ series tension controller widely used motor rotor, transformer and other winding machine
Product Manual First, model brief introduction JDKZ series of tension controller and the Division of the integrated tension control frame composed of the following models
Model |
Applicable tension(g) |
Reference diameter(mm) |
JDKZ-AB-100 |
100-1000 |
0.12-0.45
|
JDKZ-AB-200 |
200-2000 |
0.17-0.65 |
Second, the model description:
The above products are divided into the right model and the left model. JDKZ-AB-200-R: AB (closed-loop control) -200 (2000 grams of hysteresis) -R (right model) JDKZ-AB-200-L: AB (closed-loop control) -200 (2000 grams of hysteresis) -L (left model) Customers can choose the right model according to the position of the machine.
Third, the main technical parameters Power supply: DC24V ± 1V Machine power consumption: ≤ 4W Output signal: voltage 0-23.5V current 0 - 0.6A use of the environment: temperature 0-50 ℃ humidity ≤ 85% Storage temperature: Room temperature preservation
Fourth, the panel instructions Front Panel Introduction
 
Front Panel Operation: 1. Initial interface. In the figure above, position 1 shows the set tension, position 2 shows the real-time tension. The actions that can be performed at this time are: A: Short press "SET" button. The "Set tension" screen appears. In the tension setting interface, the status indicator lights up B: long press "T" button. Perform a clear operation. The flag for the success of the clear operation flashes for the status indicator. 2. Set the tension interface. The actions that can be performed at this time are: A: Data adjustment The tension interface is set. The corresponding adjustment bit will flash continuously. The shift bit can be selected by "Shift Left" (key 4) or "Right shift" (key 8). After selecting the adjustment bit, the data can be adjusted by "Data Plus" (key No. 3) or "Data subtraction" (key No. 5). B: Short press "SET" button to enter the voltage adjustment interface. Voltage adjustment interface, the status indicator switch to red. 3. Voltage adjustment interface. At this point you can operate is: A: Voltage adjustment In the voltage adjustment interface. The default display is "21.00". "2" for the interface logo, can not be adjusted. The remaining three can be adjusted. The corresponding adjustment bit will flash continuously. The shift bit can be selected by "Shift Left" (key 4) or "Right shift" (key 8). After selecting the adjustment bit, the data can be adjusted by "Data Plus" (key No. 3) or "Data subtraction" (key No. 5). Output voltage and set value is proportional to the relationship. B: Short press "SET" button, exit the adjustment interface. The status indicator turns off.
Introduction to the rear panel

The rear port is the wiring port: The top port for the 2-pin power connector: the top for the input power of the cathode, the following is the negative input power. The middle port for the 4-pin socket: the top two are the hysteresis interface. Regardless of positive and negative polarity The following two for the online communication interface. The following USB jacks: Computer connector. Computer-side need to configure the USB to 485 communication module JDKZ closed-loop control tension frame line map:

|