Closed-loop control tension frame JDK-MB instructions
【Font size: 16 14 12
2016-10-12 14:11:03
Have read 1116

Product Description
First, model brief introduction
JDK series tension controller and the Division of the integrated tension control frame composed of the following models

 

Model
Applicable tension(g)
Reference diameter(mm)
JDK-AB-005
15-100
0.05-0.12
JDK-AB-030
40-300
0.07-0.22
JDK-AB-050
50-500
0.08-0.28
JDK-AB-100
100-1000
0.12-0.45
JDK-AB-200
200-2000
0.17-0.65

 

Second, the model description: The above products are divided into the right model and left model.
JDK-MB-200-R: MB (analog input control) -200 (2000 grams of hysteresis) -R (right model)
JDK-MB-200-L: MB (analog input control) -200 (2000g hysteresis) -L (left model)
Customers can choose the right model according to the position of the machine.


Third, the main technical parameters
Power supply: DC24V ± 1V
Machine power consumption: ≤ 4W
Output signal: voltage 0-23.5V current 0 - 0.6A
use of the environment: temperature 0-50 ℃ humidity ≤ 85%
Storage temperature: Room temperature preservation
 

Fourth, the panel instructions
Front Panel Introduction

 

 

Front Panel Operation:
1. Initial interface. In the figure above, position 1 shows the set tension, position 2 shows the real-time tension. The actions that can be performed at this time are:
A: Short press "SET" button. Enter "Voltage Adjustment Interface" interface. In the voltage adjustment interface, the status indicator is lit red
B: long press "T" button. Perform a clear operation. The flag for the success of the clear operation flashes for the status indicator.
2. Voltage adjustment interface. At this point you can operate is:
A: Voltage adjustment
In the voltage adjustment interface. The default display is "21.00". "2" for the interface logo, can not be adjusted. The remaining three can be adjusted.
The corresponding adjustment bit will flash continuously. The shift bit can be selected by "Shift Left" (key 4) or "Right shift" (key 8).
After selecting the adjustment bit, the data can be adjusted by "Data Plus" (key No. 3) or "Data subtraction" (key No. 5).
Output voltage and set value is proportional to the relationship.
B: Short press "SET" button, exit the adjustment interface. The status indicator turns off.


Introduction to the rear panel

 

 

The rear port is the wiring port:
The top port for the 2-pin power connector: the top for the input power of the cathode, the following is the negative input power.
The middle port for the 4-pin socket: the top two are the hysteresis interface. Regardless of positive and negative polarity
The following two for the control voltage input interface, voltage (0-5V).
The following USB jacks: Computer connector. Computer-side need to configure the USB to 485 communication module