Instructions for use:

  1: The first level of tension Monitor installed near the product that needs winding end, out packing boxes of green connectors.
        DC24V positive -------- 7 feet-bit access
        DC24V negative -------- 8 feet-bit access
   2, press the zero key (the program will automatically set the tension value of zero).
   3, upper and lower limits set tension value.
        1), press the SET button, the indicator lights red, the tension limit is set (set to confirm press SET).
        2), set the upper limit (see the digital display four zeros)
        Example: Suppose the upper limit value of "850 grams", the lower limit value of "620 grams"
        1), through the shift key ">" to confirm the value in the single digits or in the hundreds digit, by incrementing key "▲" to set the value of 0-9 (one hundred eight, ten 5, bits 0) .
        2), and then press the SET button to confirm, white lights set the minimum tension value.
        3), through the shift key ">" to confirm the value in the single digits or in the hundreds digit, by incrementing key "▲" to set the value of 0-9 (one hundred six, ten two, bits 0) . Then press the SET button to confirm.


Alarm

      In operation, when the tension on the tension value exceeds the set limit value indicator will blink red, (if you want an external 24V warning lights, warning lights can be put on the power cord is connected to the green connector 3 feet and 7 feet when the tension exceeds or falls below the set, the alarm light flashes).
       In operation, when the tension within the set range is no light flashes, if possible tension winding machine at standstill below the lower limit you set, if the warning light flashing is normal.


Precautions

      Do not use force to press the tension pulley in the three monitor precision guide wheel in the middle, because the connection is behind the sophisticated sensors, if the external force is greater than the range of the sensor will cause tension display does not work or show damage tension failure.