Instructions for use:

   1: The first level of tension Monitor installed near the product that needs winding end, out packing boxes of green connectors.
        DC24V positive -------- 7 feet-bit access
        DC24V negative -------- 8 feet-bit access
   2: hysteresis or magnetic clutch connection:
        Hysteresis or magnetic brakes -------- 5 feet-bit access
        Hysteresis or magnetic brakes -------- 6 feet-bit access
        This connection is not positive and negative.
   3: Tension setting:
        Step one:
               1-- horizontally fixed the product on the shelf and the tension between the winding machine, to ensure that the shelf does not shake loose as possible in a straight line position. Height as far as two points in the middle height.
               2-- sure the wiring is correct, 7 and 8 are both negative terminal port can not be reversed, such as the reverse will directly lead to damage to the instrument.
        Step two:
               1 - power on, the instrument displays the value at this time is "0" (see below)

                     
              2 - If the display is not "0", but the other figures, this is due to high-precision sensors detect gravitational relationship, which is a normal phenomenon.
               3 - press and hold the "T" zero button, then the above will be bright red, says cleared completed.
        Step three:
               The method according to schematic complete wire threading, then winding machine from the tensioner to the Monitor.
               (Note: must be cleared before threading, or wire tension sensor will overlay effect).
        Step four: Tension setting:
               1 - Press the "SET" key to enter the function setting mode.
               2 - this time a long bright white light, long bright white light that enter the tension setting state (see Figure 1)
         

    
                                       (see Figure 1)     

              3 - Press the button to select the following two tension values ​​they need (Figure 2).

                    
                                        (Figure II)

              4 - For example: Now you need to set 530 grams, then by selecting the two keys to the "530" on it, as shown below (see Figure 3)

                   
                                             (Figure 3)

              5 - After selecting tension Press "SET" (see figure IV) on the tension setting is completed. 
              6 - At this point the display interface will automatically enter the next menu (see Figure E)
 
                     (Figure 4)    (Figure 5)

       This menu function is fine-tuning feature that is on the brand and the Magnetic hysteresis lag actuator performance difference of a regulation, this product factory setting value is "10" as to meet the requirements, you do not need to adjust the .
        Step Five: fine-tuning the program
               1- press "SET" button to enter a long red light, in the winding machine work by adjusting the menu "2" tension fine tuning "10" (trim value "01-40," the greater the value the greater the contrary side tension tension smaller) by fine-tuning to precisely lock tension tension values ​​you set, set up after the data is automatically saved. (See figure VI)


                            (Figure 6)

          Upon completion of the above settings to fine-tune press the SET button to exit the setting mode, then all the settings is complete.
               2-- hold down the ">" button for three seconds (the following features open):
                      Red light: tension value and hysteresis or magnetic clutch corresponding (example: hysteresis is to 0.5N, set 5000 grams in tension Monitor, this correspondence.)

Tension hysteresis range

Corresponding hysteresis settings

50克(0.005N)

“0050”

100克(0.01N)

“0100”

300克(0.03N)

“0300”

1000克(0.1N)

“1000”

5000克(0.5N)

“5000”

10000克(1.0N)

“10000”


              3-- press "SET" key to switch to the function "1" corresponds to the hysteresis or magnetic clutch by setting the initial value range. (1050)
"1" represents enter the function menu "1", "050" according to the settings and hysteresis or magnetic powder clutch tension corresponding value (example: hysteresis is to 0.5N, when the red light on the tension Monitor set 5000 grams, this corresponds to) set as shown below:

Tension hysteresis range

Setting the initial value

50克(0.005N)

“005”

100-300克(0.01-0.03N)

“010”

300-1000克(0.03-0.1N)

“030”

1000-5000克(0.1-0.5N)

“050”

5000-10000克(0.5-1.0N)

“100”

Note:

      Do not use force to press the tension pulley in the three monitor precision guide wheel in the middle, because the connection is behind the sophisticated sensors, if the external force is greater than the range of the sensor will cause tension display does not work or show damage tension failure.